NMEACHAR Control

NMEACHAR Control

The NMEACHAR Type is used on a User Defined Form to automatically collect character data from an NMEA string

An NMEA module should be included in the PAMGuard configuration to acquire NMEA data from a serial port

Required Fields

Order

The order in which the controls are read in by the program

Title

The text to be shown on the display

NMEA_Module

The name of the NMEA module from which data should be harvested

NMEA_String

The name of the NMEA string containing the data

NMEA_Position

The position of the data item in the NMEA string. Strings are comma separated, the 0’th item will be the string name, the 1’st item the one after that, etc.

Length

Length of the input field in characters

Optional Fields

Autoupdate

This control will update on a time if a non-null positive integer value is entered in the Autoupdate column. The number is the number of seconds between auto-updates

Autoclear

The control is automatically cleared when data is saved

DbTitle

Column heading for the output database. (This will default to the Title if this filed is not completed)

Hint

Text for a hint to be displayed when entering data in the control

PostTitle

Additional text to display after the input box.

Required

Forces the user to fill in the input box before the form can be saved

Plot

Data from this form can be plotted if the value is non-zero. Note that there are extensive plot options available from the Display / Logger forms menu.

Back to form Design